J.H. Larson Company | |
![]() |
||
| Acme Buck-Boost Transformer Selection
Chart 120x240 Volts Primary–16/32 Volts Secondary |
||
| Single Phase | BOOSTING | BUCKING | |||||||||||||
| Line Voltage (Available) | 95 | 100 | 105 | 208 | 215 | 215 | 220 | 225 | 135 | 240 | 240 | 245 | 250 | 255 | |
| Load Voltage (Output) | 120 | 114 | 119 | 240 | 244 | 230 | 235 | 240 | 119 | 208 | 225 | 230 | 234 | 239 | |
| Catalog Number | Connection Diagram |
D | C | C | H | H | G | G | G | F | I | E | E | E | E |
| T-1-81054 0.05 KVA |
KVA Amps Fuse/Breaker |
0.19 1.56 6 |
0.36 3.13 6 |
0.37 3.13 6 |
0.38 1.56 6 |
0.38 1.56 6 |
0.72 3.13 6 |
0.73 3.13 6 |
0.75 3.13 6 |
0.42 3.54 6 |
0.37 1.77 3 |
0.75 3.33 6 |
0.77 3.33 6 |
0.78 3.33 6 |
0.80 3.33 6 |
| T-1-81055 0.10 KVA |
KVA Amps Fuse/Breaker |
0.38 3.13 10 |
0.71 6.25 15 |
0.74 6.25 6 |
0.75 3.13 6 |
0.76 3.13 15 |
1.44 6.25 15 |
1.47 6.25 15 |
1.50 6.25 15 |
0.84 7.08 15 |
0.74 3.54 6 |
1.50 6.67 15 |
1.53 6.67 15 |
1.56 6.67 15 |
1.59 6.67 15 |
| T-1-81056 0.15 KVA |
KVA Amps Fuse/Breaker |
0.56 4.69 10 |
1.07 9.38 15 |
1.12 9.38 15 |
1.13 4.69 10 |
1.14 4.69 10 |
2.16 9.38 15 |
2.20 9.38 15 |
2.25 9.38 15 |
1.26 10.63 15 |
1.11 5.31 6 |
2.25 10.00 15 |
2.30 10.00 15 |
2.34 10.00 15 |
2.39 10.00 15 |
| T-1-81057 0.25 KVA |
KVA Amps Fuse/Breaker |
0.94 7.81 15 |
1.78 15.63 15 |
1.86 15.63 25 |
1.88 7.81 15 |
1.91 7.81 15 |
3.59 15.63 25 |
3.67 15.63 25 |
3.75 15.63 25 |
2.11 17.71 20 |
1.84 8.85 15 |
3.75 16.67 20 |
3.83 16.67 20 |
3.90 16.67 20 |
3.98 16.67 20 |
| T-1-81059 0.75 KVA |
KVA Amps Fuse/Breaker |
2.81 23.44 40 |
5.34 46.88 70 |
5.58 46.88 70 |
5.63 23.44 40 |
5.72 23.44 40 |
10.78 46.88 70 |
11.02 46.88 70 |
11.25 46.88 70 |
6.23 53.13 60 |
5.53 26.56 30 |
11.25 50.00 60 |
11.50 50.00 60 |
11.70 50.00 60 |
11.95 50.00 60 |
| T-1-13073 1.00 KVA |
KVA Amps Fuse/Breaker |
3.75 31.25 50 |
7.13 62.50 90 |
7.44 62.50 90 |
7.50 31.25 50 |
7.63 31.25 50 |
14.38 62.50 90 |
14.69 62.50 90 |
15.00 62.50 90 |
8.43 70.83 80 |
7.37 35.42 40 |
15.00 66.67 80 |
15.33 66.67 80 |
15.60 66.67 80 |
15.93 66.67 80 |
| T-1-13074 1.50 KVA |
KVA Amps Fuse/Breaker |
5.63 46.90 80 |
10.69 93.80 150 |
11.16 93.80 150 |
11.25 46.90 70 |
11.44 46.90 80 |
21.56 93.80 125 |
22.03 93.80 125 |
22.50 93.80 125 |
12.64 106.30 125 |
11.05 53.10 60 |
22.50 100.00 125 |
23.00 100.00 125 |
23.40 100.00 125 |
23.90 100.00 125 |
| T-1-13075 2.00 KVA |
KVA Amps Fuse/Breaker |
7.50 62.50 100 |
14.25 125.00 200 |
14.88 125.00 200 |
15.00 62.50 90 |
15.25 62.50 90 |
28.75 125.00 175 |
29.38 125.00 175 |
30.00 125.00 175 |
16.86 141.70 175 |
14.73 70.80 80 |
30.00 133.30 175 |
30.67 133.30 175 |
31.20 133.30 175 |
31.87 133.30 175 |
| T-1-13076 3.00 KVA |
KVA Amps Fuse/Breaker |
11.25 93.80 150 |
21.38 187.50 300 |
22.31 187.50 300 |
22.50 93.80 150 |
22.88 93.80 150 |
43.13 187.50 250 |
44.06 187.50 250 |
45.00 187.50 250 |
25.29 212.50 125 |
22.10 106.30 250 |
45.00 200.00 250 |
46.00 200.00 250 |
46.80 200.00 250 |
47.80 200.00 250 |
| T-1-13077 5.00 KVA |
KVA Amps Fuse/Breaker |
18.75 156.30 250 |
35.63 312.50 450 |
37.19 312.50 450 |
37.50 156.30 225 |
38.13 156.30 225 |
71.88 312.50 450 |
73.44 312.50 450 |
75.00 312.50 450 |
42.15 354.20 400 |
36.83 177.10 200 |
75.00 333.30 400 |
76.67 333.30 400 |
78.00 333.30 400 |
79.67 333.30 400 |
| T-1-13078[1] 7.50 KVA |
KVA Amps Fuse/Breaker |
28.10 234.40 400 |
53.40 468.80 700 |
55.80 468.80 700 |
56.30 234.40 350 |
57.20 234.40 350 |
107.80 468.80 700 |
110.20 468.80 700 |
112.50 468.80 700 |
63.20 531.30 600 |
55.30 265.60 300 |
112.50 500.00 600 |
115.00 500.00 600 |
117.00 500.00 600 |
119.50 500.00 600 |
| T-1-13079[1] 10.00 KVA |
KVA Amps Fuse/Breaker |
37.50 312.50 500 |
71.30 625.00 1000 |
74.40 625.00 1000 |
75.00 312.50 450 |
76.30 312.50 450 |
143.80 625.00 1000 |
146.90 625.00 1000 |
150.00 625.00 1000 |
84.30 708.30 800 |
73.70 354.20 400 |
150.00 666.70 800 |
153.40 666.70 800 |
156.00 666.70 800 |
159.30 666.70 800 |
| Catalog Number | Connection Diagram |
D | C | C | H | H | G | G | G | F | I | E | E | E | E |
| Note: | Inputs and outputs may be reversed; KVA remains constant. All applications in black are suitable for 50/60 Hz. All applications in red are suitable for 60 Hz. only. |
| [1] | It is necessary to utilize multiple conductors on the secondary (X1, X2, X3, and X4) terminals of these transformers. |